Page 1 - SUPER

®SuperWorkstation5038A-IL SUPERUSER’S MANUAL1.0

Page 2 - Release Date: June 14, 2013

SuperWorkstation 5038A-IL User's Manual1-21-2 Serverboard FeaturesAt the heart of the SuperWorkstation 5038A-IL lies the X10SAE, a single process

Page 3 - Manual Organization

7-18SuperWorkstation 5038A-IL User's ManualIf the item above - SATA Mode Select is set to IDE, the following items are displayed:Serial ATA Port

Page 4

Chapter 7: BIOS7-19PCI Latency TimerThis feature sets the latency timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to

Page 5

7-20SuperWorkstation 5038A-IL User's ManualOnboard LAN1/LAN2 Option ROMSelect iSCSI to use the iSCSI Option ROM to boot the computer using an iSC

Page 6 - Table of Contents

Chapter 7: BIOS7-21TPM StateSelect Enabled to use TPM (Trusted Platform Module) settings for system data security. The options are Disabled and Enable

Page 7

7-22SuperWorkstation 5038A-IL User's ManualFirmware Update Confi gurationME FW Image Re-FlashSelect Enable to re-fl ash the ME (Management Engine)

Page 8

Chapter 7: BIOS7-23Change (Serial Port 1 / Serial Port 2) SettingsThis option specifi es the base I/O port address and the Interrupt Request address of

Page 9 - Introduction

7-24SuperWorkstation 5038A-IL User's Manual• VDIMM• 5Vcc • PCH 1.05V • AVCC• 3.3Vcc • VSB • VBATSerial Port Console RedirectionCOM1/COM2Use thi

Page 10 - 1-2 Serverboard Features

Chapter 7: BIOS7-25ParityA parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is se

Page 11 - 1-3 Chassis Features

7-26SuperWorkstation 5038A-IL User's ManualRedirection After BIOS PostUse this feature to enable or disable legacy console redirection after BIOS

Page 12 - System Block Diagram

Chapter 7: BIOS7-277-4 Event LogsChange SMBIOS Event Log SettingsEnabling/Disabling OptionsSMBIOS Event LogChange this item to enable or disable all

Page 13 - 1-4 Contacting Supermicro

1-3Chapter 1: Introduction1-3 Chassis FeaturesThe SC732D4F-500B is mid-tower chassis. The following is a general outline of the main features of the c

Page 14

7-28SuperWorkstation 5038A-IL User's ManualWhen Log is FullSelect Erase Immediately for all messages to be automatically erased from the event l

Page 15 - Installation

Chapter 7: BIOS7-297-5 Boot SettingsUse this feature to confi gure Boot Settings:Set Boot PriorityThis option prioritizes the order of bootable devices

Page 16

7-30SuperWorkstation 5038A-IL User's Manual Delete Boot OptionUse this feature to remove a pre-defi ned boot device from which the system will bo

Page 17 - • One microphone port

Chapter 7: BIOS7-317-6 Security SettingsThis menu allows the user to confi gure the following security settings for the system.Main Advanced SecurityBo

Page 18 - 3-4 Control Panel LEDs

7-32SuperWorkstation 5038A-IL User's Manual7-7 Save & ExitSelect the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS Setu

Page 19 - Overheat/Fan Fail

Chapter 7: BIOS7-33Save As User DefaultsTo set this feature, select Save as User Defaults from the Exit menu and press <En-ter>. This enables th

Page 20

7-34SuperWorkstation 5038A-IL User's ManualNotes

Page 21 - Chapter 4

Appendix A: POST Error Beep CodesA-1Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Page 22

A-2SuperWorkstation 5038A-IL User's ManualNotes

Page 23 - ﺔﻴﺋﺎﺑﺮﻬﻜﻟﺍ

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorOne Intel E3-1200V3 series processor or 4th Generation Intel Core™ i7/i5/

Page 24 - Installation Instructions

SuperWorkstation 5038A-IL User's Manual1-4Figure 1-1. Intel C226 Chipset: System Block DiagramNote: This is a general block diagram. Please see

Page 25 - 250 V, 20 A

B-2SuperWorkstation 5038A-IL User's ManualServerboardX10SAEDimensions: 12" x 9.6" (305 x 244 mm)ChassisSC732D4F-500B Form Factor: mid t

Page 26 - Power Disconnection Warning

B-3Appendix B: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR 22 Class B

Page 27 - ילמשח קותינ ינפמ הרהזא

B-4SuperWorkstation 5038A-IL User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life

Page 28 - Equipment Installation

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408

Page 29 - Restricted Area

SuperWorkstation 5038A-IL User's Manual1-6Notes

Page 30 - Battery Handling

Chapter 2: Installation2-1Chapter 2 Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperWorkstation 5038A-IL up and

Page 31

2-2SuperWorkstation 5038A-IL User's ManualFigure 2-1. Removing the Chassis Side Covers131622152-3 Accessing the Inside of the SystemYou may nee

Page 32 - Redundant Power Supplies

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThe control panel on the 5038A-IL has several LEDs and a power button. These LEDs

Page 33 - Backplane Voltage

3-2SuperWorkstation 5038A-IL User's ManualHDDIndicates IDE channel activity on the SAS, SATA and/or DVD-ROM drive when fl ashing.NICIndicates netw

Page 34

Chapter 3: System Interface3-3Overheat/Fan FailWhen this LED fl ashes, it indicates a chassis fan failure. When on continuously it indicates an overhea

Page 35 - Product Disposal

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Page 36 - רצומה קוליס

3-4SuperWorkstation 5038A-IL User's ManualNotes

Page 37

4-1Chapter 4: Warning Statements for AC SystemsChapter 4Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe fo

Page 38 - Power Cable and AC Adapter

4-2SuperWorkstation 5038A-IL User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situa

Page 39 - (UL/CSA ﻞﻤﺤﺗ ﻲﺘﻟﺍﺔﻣﻼﻋ )

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확

Page 40

4-4SuperWorkstation 5038A-IL User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the system to th

Page 41 - Advanced Serverboard Setup

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Page 42 - • Control Panel cable (JF1)

4-6SuperWorkstation 5038A-IL User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソースから切断され、電

Page 43 - 5-3 I/O Ports

4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu

Page 44

4-8SuperWorkstation 5038A-IL User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained and qual

Page 45 - CPU Pin 1

4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユ ニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Th

Page 46 - Installing the Heatsink

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Page 47 - Removing the Heatsink

4-10SuperWorkstation 5038A-IL User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly. Repl

Page 48

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Page 49 - Memory Population Guidelines

4-12SuperWorkstation 5038A-IL User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein t

Page 50

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能

Page 51 - 5-6 Adding PCI Add-On Cards

4-14SuperWorkstation 5038A-IL User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must comply with

Page 52 - A-SATA1 (3.0)

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Page 53

4-16SuperWorkstation 5038A-IL User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met

Page 54 - 5-8 Connector Defi nitions

4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt

Page 55

4-18SuperWorkstation 5038A-IL User's Manual Warning!When installing the product, use the provided or designated connection cables, power cables a

Page 56

4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné

Page 57 - (NC: No Connection)

SuperWorkstation 5038A-IL User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X10SAE serverboard,

Page 58

4-20SuperWorkstation 5038A-IL User's ManualNotes

Page 59

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cable

Page 60

5-2SuperWorkstation 5038A-IL User's Manual5-2 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to t

Page 61 - 5-9 Jumper Settings

Chapter 5: Advanced Serverboard Setup5-35-3 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below

Page 62

5-4SuperWorkstation 5038A-IL User's Manual5-4 Processor and Heatsink InstallationWarning: When handling the processor package, avoid placing dir

Page 63

Chapter 5: Advanced Serverboard Setup5-55. Align the CPU key, which is a semi-circle cutout, against the socket key, which is the notch below the gol

Page 64 - 5-11 SATA Ports

5-6SuperWorkstation 5038A-IL User's ManualThermal GreaseHeatsink FinsInstalling the Heatsink1. Locate the CPU Fan power connec-tor on the mother

Page 65 - 5-12 Installing Software

Chapter 5: Advanced Serverboard Setup5-78. Repeat Step 7 to insert all four heatsink fasteners into the mounting holes.9. Once all four fasteners ar

Page 66 - SuperDoctor III

5-8SuperWorkstation 5038A-IL User's Manual5-5 Installing Memory ModulesNote: Check the Supermicro web site for recommended memory modules.CAUTIO

Page 67 - 5-13 Onboard Battery

Chapter 5: Advanced Serverboard Setup5-9Memory SupportThe X10SAE supports up to 32 GB of Unbuffered ECC/Non-ECC DDR3-1600/1066 MHz memory in four DIMM

Page 68

vPrefaceNotes

Page 69 - Advanced Chassis Setup

5-10SuperWorkstation 5038A-IL User's Manual• For Microsoft Windows users: Microsoft implemented a design change in Windows XP with Service Pack 2

Page 70

Chapter 5: Advanced Serverboard Setup5-115-6 Adding PCI Add-On CardsThe 5038A-IL can accommodate standard size add-on cards populated in all slots on

Page 71 - HDD Cage (B)

5-12SuperWorkstation 5038A-IL User's ManualFigure 5-4. X10SAE Layout5-7 Serverboard DetailsX10SAERev. 1.01AUDIO FPJPAC1JSPDIF_OUTCOM4COM1LV33JWOR

Page 72 - Release Tabs

Chapter 5: Advanced Serverboard Setup5-13Connector Description1394_1/2 1394 Connectors 1/2Audio FP Front Panel Audio HeaderHD AUDIO High-Defi nition Au

Page 73

5-14SuperWorkstation 5038A-IL User's ManualReset ConnectorThe reset header is located on pins 3 and 4 of JF1. Attach the reset switch on the comp

Page 74 - Optional

Chapter 5: Advanced Serverboard Setup5-15Overheat/Fan Fail LED (OH)Connect an LED to pins 7 and 8 of JF1 to provide advanced warning of chassis overhe

Page 75 - Thumb Screw

5-16SuperWorkstation 5038A-IL User's ManualFan HeadersThe X10SAE has fi ve fan headers (Fan 1-5), all of which are 4-pin fans. Although pins 1-3 o

Page 76

Chapter 5: Advanced Serverboard Setup5-17SGPIO HeadersTwo SGPIO (Serial General Purpose Input/Output) headers are designated T-SGPIO1 and SGPIO2. Thes

Page 77 - Cover Plate

5-18SuperWorkstation 5038A-IL User's ManualUniversal Serial Bus (USB)Four Universal Serial Bus 2.0 ports (0/1, 2/3) and two USB 3.0 ports (10/11)

Page 78 - 6-7 Installing System Fans

Chapter 5: Advanced Serverboard Setup5-19DOM PWR Connector (JSD1)The Disk-On-Module (DOM) power connector, located at JSD1, provides 5V (Gen1/Gen) pow

Page 79

viSuperWorkstation 5038A-IL User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 80

5-20SuperWorkstation 5038A-IL User's ManualIEEE 1394_1/1394_2 Connectors1394_1 and 1394_2 provide IEEE 1394 connections on the mother-board. Conn

Page 81 - 6-9 Power Supply

Chapter 5: Advanced Serverboard Setup5-215-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c

Page 82

5-22SuperWorkstation 5038A-IL User's ManualGLANJumper SettingsJumper Setting Defi nition 1-2 Enabled (default)2-3 DisabledWatch Dog Enable/Di

Page 83 - Chapter 7

Chapter 5: Advanced Serverboard Setup5-23PCI Slot_SMB EnableJumper Settings Jumper Setting Defi nition Short EnabledOpen (Default) DisabledPCI

Page 84 - 7-2 Main Setup

5-24SuperWorkstation 5038A-IL User's Manual5-10 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports on the I/O back-plane each have two LEDs. On each

Page 85

Chapter 5: Advanced Serverboard Setup5-255-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.s

Page 86 - Boot Feature

5-26SuperWorkstation 5038A-IL User's ManualSuperDoctor IIIThe SuperDoctor® III program is a web-based management tool that supports remote manage

Page 87 - Power Confi guration

Chapter 5: Advanced Serverboard Setup5-275-13 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in any way; a damaged b

Page 88 - CPU Confi guration

5-28SuperWorkstation 5038A-IL User's ManualNotes

Page 89

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform simple ma

Page 90

viiTable of ContentsCircuit Breaker ... 4-5Power Disconne

Page 91

6-2SuperWorkstation 5038A-IL User's Manual6-2 Accessing the Inside of the SystemThe SC732 features two removable side covers, allowing easy acce

Page 92

Chapter 6: Advanced Chassis Setup6-3Figure 6-2. Rotating the Hard Drive Cage6-3 Rotating the Hard Drive CageIn order to access and install component

Page 93 - • IGfx Frequency

6-4SuperWorkstation 5038A-IL User's Manual6-4 Removing and Installing 3.5" Hard DrivesThe SC732 chassis must be powered-down before hard dr

Page 94

Chapter 6: Advanced Chassis Setup6-56. If a hard drive is already present, remove it by carefully pulling the sides of the hard drive carrier outward

Page 95 - PCI-E Confi guration

6-6SuperWorkstation 5038A-IL User's ManualFigure 6-5. Installing a Hard Drive Carrier into the Hard Drive Cage11119Optional Screw

Page 96 - Memory Confi guration

Chapter 6: Advanced Chassis Setup6-7Figure 6-6. Removing a 2.5" Hard Drive1415Thumb Screw6-5 Removing and Installing 2.5" Hard DrivesAddin

Page 97 - • USB Devices

6-8SuperWorkstation 5038A-IL User's ManualFigure 6-7. Installing 2.5" Hard Drives5. If a hard drive is already present, remove it by caref

Page 98 - On Board Chip Confi guration

Chapter 6: Advanced Chassis Setup6-96-6 Installing a 3.5" DeviceThe SC732D chassis has one 3.5" device slot, which supports an optional dev

Page 99

6-10SuperWorkstation 5038A-IL User's Manual6-7 Installing System FansInstalling the Rear Exhaust Fan1. Disconnect all power to the chassis.2.

Page 100 - • Software Preserve Support

Chapter 6: Advanced Chassis Setup6-11Installing the Front Cooling Fan (Optional)1. Disconnect all power to the chassis.2. Insert the four rubber pin

Page 101

viiiSuperWorkstation 5038A-IL User's ManualChapter 6 Advanced Chassis Setup6-1 Static-Sensitive Devices ...

Page 102 - ACPI Settings

6-12SuperWorkstation 5038A-IL User's Manual6-8 Installing the Front BezelFront Bezel Installation1. Insert the tabs on the front bezel into the

Page 103 - • PTT Capability /State

Chapter 6: Advanced Chassis Setup6-136-9 Power SupplyThe SC732 chassis includes a 500 Watt power supply. In the event that it becomes necessary to rep

Page 104 - Super IO Confi guration

6-14SuperWorkstation 5038A-IL User's ManualNotes

Page 105 - H/W (Hardware) Monitor

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X10SAE. The ROM BIOS is stored in a Flash

Page 106 - Console Redirection Settings

7-2SuperWorkstation 5038A-IL User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memor

Page 107

Chapter 7: BIOS7-3The following Main menu items will display:System Time/System Date Use this option to change the system date and time. Highlight Sys

Page 108

7-4SuperWorkstation 5038A-IL User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and press <Enter> to a

Page 109 - 7-4 Event Logs

Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis feature forces the system to wait until the 'F1' key is pressed if an error oc-curs.

Page 110 - View SMBIOS Event Log

7-6SuperWorkstation 5038A-IL User's ManualCPU Confi gurationThe following CPU information will be displayed:• Type of CPU• CPU Signature• Microco

Page 111 - 7-5 Boot Settings

Chapter 7: BIOS7-7Clock Spread Spectrum If this feature is set to Enabled, the BIOS will monitor the level of Electromagnetic Interference caused by t

Page 112

Chapter 1 Introduction1-1 OverviewThe 5038A-IL is a high-end workstation comprised of two main subsystems: the SC732D4F-500B tower chassis and the X10

Page 113 - 7-6 Security Settings

7-8SuperWorkstation 5038A-IL User's ManualNote: If there is any change to this setting, you will need to reboot the system for the change to take

Page 114 - 7-7 Save & Exit

Chapter 7: BIOS7-9DDR Power Limit2 (Available when "Turbo Mode" is set to Enabled)Use this feature to set the power limit for DDR2. Use the

Page 115

7-10SuperWorkstation 5038A-IL User's ManualEnhanced C1E State (Available when "CPU C-States" is set to Enabled)Select Enabled to enable

Page 116

Chapter 7: BIOS7-11C-State Pre-WakeSelect Enabled to support C State Pre-Wake State features. The options are Enabled and DisabledPackage C-State limi

Page 117 - BIOS Error Beep Codes

7-12SuperWorkstation 5038A-IL User's ManualPrimary DisplayUse this feature to select the graphics device to be used as the primary display. You c

Page 118

Chapter 7: BIOS7-13PCI-E Confi gurationThis item displays the information of the (graphics) device installed on a PCI-E slot.SLOT6 PCI-E 3.0 x16SLOT6

Page 119 - System Specifi cations

7-14SuperWorkstation 5038A-IL User's ManualSLOT3 PCI-E 2.0 x 1 ASPM/SLOT5 PCI-E 2.0 x 1 ASPM/SLOT7 PCI-E 2.0 x 1 ASPMThis feature confi gures t

Page 120

Chapter 7: BIOS7-15Memory Frequency LimiterThis feature sets the limit of memory frequency for DIMM modules installed on the the motherboard. The opti

Page 121 - Regulatory Compliance

7-16SuperWorkstation 5038A-IL User's ManualPort 60/64 EmulationThis feature enables or disables I/O port 60h/64h emulation support. This should

Page 122

Chapter 7: BIOS7-17SATA Confi gurationWhen this submenu is selected, the AMI BIOS automatically detects the presence of the SATA Devices and displays