SUPERSuperWorkstation 5036T-T®USER’S MANUALRevision 1.0
NotesxSuperWorkstation 5036T-T User's Manual
Chapter 1 Introduction1-1 OverviewThe SuperWorkstation 5036T-T is a high-end workstation comprised of two main subsystems: the SC733TQ-465 mid-tower c
1-2SuperWorkstation 5036T-T User's Manual1-2 Serverboard FeaturesAt the heart of the SuperWorkstation 5036T-T lies the X8SAX, a single processor
1-3Chapter 1: IntroductionOther FeaturesOther onboard features that promote system health include onboard voltage moni-tors, a chassis intrusion heade
1-4SuperWorkstation 5036T-T User's ManualW83795AGH/W MonitorIntelIntelVRD 11.1SBIntelIntersil Intel 82574LQPI: Up to 6.40 GT/s LPCPCIE_x16PCI-E x
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40
1-6SuperWorkstation 5036T-T User's ManualNotes
Chapter 2: System Setup2-1Chapter 2 System Setup2-1 OverviewThis chapter provides a quick setup checklist to get your SuperWorkstation 5036T-T up and
2-2SUPERWORKSTATION 5036T-T User's ManualTo maintain proper cooling, always keep all chassis panels closed and all SATA • carriers installed when
Chapter 2: System Setup2-3Figure 2-1. Accessing the Inside of the 5036T-T
Manual Revision 1.0 Release Date: November 17, 2008The information in this User’s Manual has been carefully reviewed and is believed to be accur
2-4SUPERWORKSTATION 5036T-T User's ManualSee the installation and removal sections for the peripheral drives in Chapter 6.Check the Serial ATA di
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel and one on each Serial ATA drive carri
3-2SUPERWORKSTATION 5036T-T User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC733TQ-465 chassis has four LEDs.
Chapter 3: System Interface3-3Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make
3-4SUPERWORKSTATION 5036T-T User's ManualNotes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions shall be followed to protect
SUPERSERVER 5036T-T User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the SuperServ
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into
SUPERSERVER 5036T-T User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 5036T-T is
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8SAX serverboard in
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
5-2SuperWorkstation 5036T-T User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When
Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar
5-4SuperWorkstation 5036T-T User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2
Chapter 5: Advanced Serverboard Setup5-55-5 Processor and Heatsink InstallationWhen handling the processor package, avoid placing direct pressure on
5-6SuperWorkstation 5036T-T User's Manual!After removing the plastic cap, 1. using your thumb and the index fi nger, hold the CPU at the north and
Chapter 5: Advanced Serverboard Setup5-7Installing the Heatsink InstallationDo not apply any thermal grease to the 1. heatsink or the CPU die; the req
5-8SuperWorkstation 5036T-T User's Manual5-6 Installing Memory ModulesNote: Check the Supermicro web site for recommended memory modules.CAUTION
Chapter 5: Advanced Serverboard Setup5-9Memory SupportThe X8SAX supports up to 24 GB of unbuffered ECC/non-ECC DDR3-1600/1333/1066/800 SDRAM. Notes:Du
5-10SuperWorkstation 5036T-T User's Manual5-7 Adding PCI Add-On CardsThe 5036T-T can accommodate standard size add-on cards in all slots on the
Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. X8SAX Layout5-8 Serverboard DetailsT-SGPIO0T-SGPIO1JF1JWOLJWDJPUSB1JPACJPL2JPL1JLEDJPI1JPUSB2SPKR
SuperWorkstation 5036T-T User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8SAX serverboard, i
5-12SuperWorkstation 5036T-T User's ManualX8SAX Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 5-10)JI2C1/JI2C2 SM
Chapter 5: Advanced Serverboard Setup5-13Reset ConnectorThe reset header is located on pins 3 and 4 of JF1. Attach the reset switch on the computer ch
5-14SuperWorkstation 5036T-T User's ManualOverheat/Fan Fail LED (OH)Connect an LED to pins 7 and 8 of JF1 to provide advanced warning of chassis
Chapter 5: Advanced Serverboard Setup5-15Fan HeadersThe X8SAX has six fan headers, all of which are 4-pin fans. However, pins 1-3 of the fan headers a
5-16SuperWorkstation 5036T-T User's ManualSGPIO HeaderTwo SGPIO (Serial General Purpose Input/Output) headers are designated SGPIO0 and SGPIO1. T
Chapter 5: Advanced Serverboard Setup5-17Audio Input CD HeaderPin Defi nitions (CD-IN) Pin# Defi nition 1 Left Stereo Signal2 Ground3 Gr
5-18SuperWorkstation 5036T-T User's ManualIEEE 1394 ConnectionConnectors 1394_1 and 1394_2 provide connectivity for IEEE 1394 (Firewire) devices.
Chapter 5: Advanced Serverboard Setup5-19Overheat/Fan Fail LED (JOH1)The JOH1 header is used to connect an LED to provide warnings of chas-sis overhea
5-20SuperWorkstation 5036T-T User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be us
Chapter 5: Advanced Serverboard Setup5-21LAN1/LAN2 Enable/Disable Change the setting of jumper JPL1 or JPL2 to enable or disable the LAN1 and LAN2 Eth
vPrefaceNotes
5-22SuperWorkstation 5036T-T User's ManualUSB Wake-Up Enable/Disable Jumper Set-tings (JUSB1/JUSB2)Pin# Defi nition 1-2 Enabled 2-3 Disabl
Chapter 5: Advanced Serverboard Setup5-235-11 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each por
5-24SuperWorkstation 5036T-T User's Manual5-12 Floppy, IDE, and SATA PortsSATA PortPin Defi nitions(I-SATA0 ~ I-SATA5)Pin # Defi nitio
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform simple ma
6-2SUPERWORKSTATION 5036T-T Manual6-2 Front Control PanelThe front control panel must be connected to the JF1 connector on the motherboard to provide
Chapter 6: Advanced Chassis Setup6-3Figure 6-2. Chassis Front View5.25" Drive BaysSystem ResetMain Power SATA Active LEDSystem LEDsFront Side US
6-4SUPERWORKSTATION 5036T-T ManualFigure 6-3. Chassis Rear ViewPCI Expansion SlotsI/O Backplane (see Figure 5-2)Power Supply
Chapter 6: Advanced Chassis Setup6-56-3 System FansA 9-cm chassis cooling fan housed in a fan duct is located just below the peripheral drive bays to
6-6SUPERWORKSTATION 5036T-T ManualFigure 6-4. Removing the Fan Duct AssemblyInstalling a New FanReplace the failed fan with an identical one (availab
Chapter 6: Advanced Chassis Setup6-7Important! Use extreme caution when working around the SATA backplane. Do not touch the backplane with any metal o
viSuperWorkstation 5036T-T User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
6-8SUPERWORKSTATION 5036T-T ManualFigure 6-5. Removing a SATA Drive Carrier
Chapter 6: Advanced Chassis Setup6-9Installing Components in the 5.25" Drive BaysThe 5036T-T has two 5.25" drive bays above the SATA drive b
6-10SUPERWORKSTATION 5036T-T ManualFigure 6-6. Adding a Component Without a Drive Carrier6-5 SATA-733 Backplane Specifi cationsThe SATA backplane supp
Chapter 6: Advanced Chassis Setup6-11Figure 6-7: SATA-733 BackplaneNote: all backplane jumpers are set to their recommended default settings. For deta
6-12SUPERWORKSTATION 5036T-T Manual6-6 Power SupplyThe 5036T-T has a single 465W high-effi ciency power supply that features noise-suppression technolo
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8SAX/C7X58. The AMI ROM BIOS is stored in
7-2SuperWorkstation 5036T-T User's ManualStarting the Setup UtilityNormally, the only visible POST (Power On Self Test) routine is the memory tes
Chapter 7: BIOS7-3ProcessorThe AMI BIOS will automatically display the status of processor as shown below:SpeedPhysical CountLogical CountSystem Memor
7-4SuperWorkstation 5036T-T User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter> to acce
Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The opti
viiTable of Contents4-3 ESD Precautions ... 4-34-4 Operating
7-6SuperWorkstation 5036T-T User's ManualClock-Spread SpectrumSelect Enable to use the feature of Clock Spectrum, which will allow the BIOS to mo
Chapter 7: BIOS7-7tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable: Disable GV3 and Enab
7-8SuperWorkstation 5036T-T User's ManualC0 - Active. The CPU is processing instructions.C1 - Auto Halt. The core clock (CPU) is off. This is
Chapter 7: BIOS7-9DCA Prefetch DelayA DCA Prefetch is used with TOE components to prefetch data in order to shorten execution cycles and maximize data
7-10SuperWorkstation 5036T-T User's ManualLockstep - The motherboard uses two areas of memory to run the same set of operations in parallel.Spari
Chapter 7: BIOS7-11Air FlowThis is the air fl ow speed to the DIMM modules. Each step is in mm/sec. The default is [1500]. Press "+" or &q
7-12SuperWorkstation 5036T-T User's ManualIntel I/OATThe Intel I/OAT (I/O Acceleration Technology) signifi cantly reduces CPU overhead by leveragi
Chapter 7: BIOS7-13XIDE / Floppy Confi gurationWhen this submenu is selected, the AMI BIOS automatically detects the presence of the IDE Devices and di
7-14SuperWorkstation 5036T-T User's ManualPrimary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master, and fourth IDE MasterThese sett
Chapter 7: BIOS7-15to use Single Word DMA mode 0. It has a data transfer rate of 2.1 MBs. Select SWDMA1 to allow the BIOS to use Single Word DMA mode
viiiSuperWorkstation 5036T-T User's ManualCD and Audio FP ... 5
7-16SuperWorkstation 5036T-T User's ManualPCI Latency TimerThis feature sets the latency Timer of each PCI device installed on a PCI bus. Select
Chapter 7: BIOS7-17devices. ASK IR (Amplitude Shifted Keying Infra-Red) is a protocol compatible with Sharp® branded PDAs and other infra-red devices
7-18SuperWorkstation 5036T-T User's ManualSredir Memory Display DelayThis feature defi nes the length of time in seconds to display memory informa
Chapter 7: BIOS7-19XACPI Confi gurationUse this feature to confi gure ACPI (Advanced Confi guration and Power Interface) power management settings for yo
7-20SuperWorkstation 5036T-T User's Manual7-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you use both pass-words
Chapter 7: BIOS7-217-5 Boot Confi gurationUse this feature to confi gure Boot Settings:XBoot Device PriorityThis feature allows the user to specify the
7-22SuperWorkstation 5036T-T User's Manual7-6 Exit OptionsSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup
Chapter 7: BIOS7-23Load Optimal DefaultsTo set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, select OK
7-24SuperWorkstation 5036T-T User's ManualNotes
Appendix A: POST Error Beep CodesA-1Appendix A POST Error Beep CodesThis section lists POST (Power On Self Test) error beep codes for the Phoenix BIOS
Installing Components in the 5.25" Drive Bays ... 6-96-5 SATA-733 Backplane Specifi cations ...
A-2SuperWorkstation 5036T-T User's ManualNotes
Appendix B: Software Installation InstructionsB-1Appendix B Software Installation InstructionsB-1 Installing DriversAfter you've installed the Wi
B-2SuperWorkstation 5036T-T User's ManualSupero Doctor III Interface Display Screen-I (Health Information)B-2 Confi guring Supero Doctor IIIThe Su
Appendix B: Software Installation InstructionsB-3Supero Doctor III Interface Display Screen-II (Remote Control)Note: SD III Software Revision 1.0 can
B-4SuperWorkstation 5036T-T User's ManualNotes
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors One Intel Core™ i7 Xeon® or future Intel Nehalem processor famili
C-2SuperWorkstation 5036T-T User's ManualWeight Gross (Bare Bone): 43 lbs. (19.5 kg.)System Cooling Six (6) paired sets of 4-cm cou
C-3Appendix C: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR
C-4SuperWorkstation 5036T-T User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life
Commentaires sur ces manuels