X8DTL-3 X8DTL-i USER’S MANUALRevision 1.2 X8DTL-3FX8DTL-iF
1-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF Image Note: The drawings and pictures shown in this man
Chapter 1: Introduction1-3NotesThe DOM Power connector (JWF1) and the Wake-On-Ring header (JWOR), 1. are supported by the PCB Rev. 2.01 or a newer ver
1-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJumpers not indicated are for test purposes only. • " " indicates the location of
Chapter 1: Introduction1-5X8DTL-3/X8DTL-3F/ X8DTL-i/ X8DTL-iF Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear Open (Normal)JI2C1/JI2C
1-6 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualMotherboard Features CPUTwo Intel• ® 5500/5600* Series (LGA 1366) processors, each processor
Chapter 1: Introduction1-7ACPI Features Slow blinking LED for suspend state indicator• Main switch override mechanism• ACPI Power Management• Keyboard
1-8 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualBlock Diagram of the 5500 ChipsetNote: This is a general block diagram. Please see the previ
Chapter 1: Introduction1-91-2 Chipset OverviewBuilt upon the functionality and the capability of the 5500 platform, the X8DTL-3/X8DTL-i/X8DTL-3F/X8D
1-10 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual1-3 Special FeaturesRecovery from AC Power LossBIOS provides a setting for you to determi
Chapter 1: Introduction1-11notify the user of certain system events. For example, you can also confi gure Supero Doctor to provide you with warnings wh
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
1-12 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualWOL capability. In addition, an onboard LAN controller can also support WOL without any con
Chapter 1: Introduction1-13control capability and a processor interrupt system. Both UARTs provide legacy speed with baud rate of up to 115.2 Kbps as
1-14 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualNotes
Chapter 2: Installation2-1Chapter 2 Installation 2-1 Static-Sensitive DevicesElectrostatic Discharge (ESD) can damage electronic com ponents. To pre
2-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualLocate the matching mounting holes on the chassis. Align the mounting holes 3. on
Chapter 2: Installation2-32-3 Processor and Heatsink InstallationWhen handling the processor package, avoid placing direct pressure on the label are
2-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Socket KeysAfter removing the plastic cap, 1. using your thumb and the index fi ng
Chapter 2: Installation2-5Installing a CPU HeatsinkScrew#1Screw#2Do not apply any thermal 1. grease to the heatsink or the CPU die because the require
2-6 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualRemoving the HeatsinkWarning: We do not recommend that the CPU or the heatsink be
Chapter 2: Installation2-7X8DTL SeriesRev. 2.012-4 Installing and Removing the Memory ModulesNote: Check the Supermicro web site for recommended mem
PrefaceAbout this ManualThis manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the inst
2-8 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualMemory SupportThe X8DTL-3/-i/-3F/iF supports up to 96 GB Registered ECC or up to 2
Chapter 2: Installation2-9Memory Support for the Motherboard w/5600 Processors Installed1.5V Registered DIMMs (for the PCB R2.01 or a later version bo
2-10 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualPossible System Memory Allocation & AvailabilitySystem Device Size Physical M
Chapter 2: Installation2-11JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0
2-12 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and PS/2 mouse are lo
Chapter 2: Installation2-131. Backpanel USB 02. Backpanel USB 13. Front Panel USB 2/34. Front Panel USB 4/55. Front Panel USB 6Universal Serial Bus (U
2-14 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualSerial PortsTwo COM connections (COM1 & COM2) are located on the motherboard.
Chapter 2: Installation2-151. LAN12. LAN23. LAN5 (X8DTL-3F/iF only)Ethernet PortsTwo Ethernet ports (LAN 1/LAN2) are located at on the IO backplane. I
2-16 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual2. Front Control PanelJF1 contains header pins for various buttons and indicators
Chapter 2: Installation2-17Power ButtonOH/Fan Fail LED1NIC1 LEDReset Button2Power Fail LEDHDD LEDPower LEDResetPWRVccVccVccVcc/Front UID LEDGroundGrou
Danger/Caution: Instructions to be strictly followed to prevent catastrophic system failure or to avoid bodily injury.Warning: Important information g
2-18 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualPower ButtonOH/Fan Fail LED1NIC1 LEDReset Button2Power Fail LEDHDD LEDPower LEDRe
Chapter 2: Installation2-19Power ButtonOH/Fan Fail LED1NIC1 LEDReset Button2Power Fail LEDHDD LEDPower LEDResetPWRVccVccVccVcc/Front UID LEDGroundGrou
2-20 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualPower ButtonOH/Fan Fail LED1NIC1 LEDReset Button2Power Fail LEDHDD LEDPower LEDRe
Chapter 2: Installation2-21JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0
2-22 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP
Chapter 2: Installation2-23JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0
2-24 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP
Chapter 2: Installation2-25JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0
2-26 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP
Chapter 2: Installation2-27JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0
Contacting SupermicrovContacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408) 503-8
2-28 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualWake-On-RingThe Wake-On-Ring header is desig-nated JWOR, which will allow your sy
Chapter 2: Installation2-29JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0
2-30 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP
Chapter 2: Installation2-31JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0
2-32 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP
Chapter 2: Installation2-33JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0
2-34 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP
Chapter 2: Installation2-35JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0
2-36 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP
3-1Chapter 3: TroubleshootingChapter 3 Troubleshooting 3-1 Troubleshooting ProceduresUse the following procedures to troubleshoot your system. If you
X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualviTable of ContentsPrefaceChapter 1 Introduction1-1 Overview ...
3-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualUse the speaker to determine if any beep codes exist. Refer to the Appendix 2. for details on
3-3Chapter 3: Troubleshootingusers, so it is best to fi rst check with your distributor or reseller for troubleshooting services. They should know of a
3-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manualwarning message and the information on how to update your BIOS on our web site. Select your mo
Chapter 4: AMI BIOS4-1Chapter 4 BIOS 4-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF mot
4-2X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the m
Chapter 4: AMI BIOS4-3Supermicro X8DTL-3/i/3F/iFVersion• : This item displays the BIOS revision used in your system.Build Date• : This item displays
4-4X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual4-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter>
Chapter 4: AMI BIOS4-5Hit 'Del' Message DisplayIf this feature is set to Enabled, the message: "Press DEL to run Setup" will be di
4-6X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualRTC Alarm Time (Available if Resume on RTC Alarm is Enabled)Set the time when the system wakes
Chapter 4: AMI BIOS4-7L1 Data Prefetch (Available when supported by the CPU)Select Enabled to enable Level 1 data prefetch support to enhance system p
Table of ContentsviiReset Button ... 2-20Power Button ...
4-8X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualActive Processor CoresSet to Enabled to use a processor's Second Core and beyond. (Please
Chapter 4: AMI BIOS4-9Advanced Chipset ControlCPU Bridge Confi gurationThis feature allows the user to confi gure CPU Bridge settings.CPU Revision• :
4-10X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualMemory FrequencyThis feature forces a DDR3 memory module to run at a specifi c frequency. The a
Chapter 4: AMI BIOS4-11DCA Prefetch DelayA DCA Prefetch is used with TOE components to prefetch data in order to shorten execution cycles and maximize
4-12X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualUSB 2.0 Controller ModeThis setting allows you to select the USB 2.0 Controller mode. The opti
Chapter 4: AMI BIOS4-13SATA#2 Confi guration (Available when the option "IDE" is selected)Selecting Enhanced will set SATA#2 to native SATA m
4-14X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualPIO Mode Select OptionsOption Selected PIO Mode Max. Transfer Rate0 PIO Mode 0 3.3 MB/s1 PIO M
Chapter 4: AMI BIOS4-15PCI/PnP Confi guration Clear NVRAMSelect Yes to clear the Non-Volatile Random Access (Flash) Memory (NVRAM) during system boot.
4-16X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualLoad Onboard SAS Option ROM (Available when SAS is enabled on the X8DTL-3/-3F)Select Enabled t
Chapter 4: AMI BIOS4-17Flow ControlThis feature allows the user to set the fl ow control for Console Redirection. The options are None, Hardware, and S
X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualviiiNo Power ...
4-18X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualThe Default Alarm• : Select this setting to trigger the CPU overheat alarm (in-cluding the LE
Chapter 4: AMI BIOS4-19(i.e., by increasing CPU Fan speed, triggering the Overheat Alarm, etc). Since CPUs can have different ‘Temperature Tolerances’
4-20X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualACPI Confi gurationUse this feature to confi gure Advanced Confi guration and Power Interface (A
Chapter 4: AMI BIOS4-21errors on Windows platforms in order to reduce system crashes due to hardware errors and to enhance system recovery and health
4-22X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualIPMI Confi guration (For X8DTL-3F/iF only)Intelligent Platform Management Interface (IPMI) is
Chapter 4: AMI BIOS4-23Caution: Make sure that you no longer need any data stored in the event log before clearing the BMC Event Log because you will
4-24X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualMark all events as readSelect "OK" to mark all events as read. The options are OK an
Chapter 4: AMI BIOS4-25Change Supervisor PasswordSelect this feature and press <Enter> to access the submenu, and then enter a new Supervisor Pa
4-26X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualBoot Device PriorityThis feature allows the user to specify the priority sequence of boot dev
Chapter 4: AMI BIOS4-27Save Changes and ExitAfter confi guring the setup settings, select this option to save the changes and exit the BIOS Setup Utili
Chapter 1: Introduction1-1Chapter 1 Introduction 1-1 OverviewChecklistCongratulations on purchasing your computer motherboard from an acknowledged lea
4-28X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualNotes
A-1Appendix A: BIOS POST Error CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualNotes
Appendix B: Software Installation InstructionsB-1Driver/Tool Installation Display ScreenNote 1. Click the icons showing a hand writing on the paper to
B-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualSupero Doctor III Interface Display Screen-I (Health Information)B-2 Confi guring Supero Doctor
Appendix B: Software Installation InstructionsB-3Supero Doctor III Interface Display Screen-II (Remote Control)Note: SD III Software Revision 1.0 can
B-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualNotes
(Disclaimer Continued)The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear fa