X8DTL-3 X8DTL-i USER’S MANUALRevision 1.2 X8DTL-3FX8DTL-iF

Page 2 - Release Date: Dec. 1, 2010

1-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF Image Note: The drawings and pictures shown in this man

Page 3 - Manual Organization

Chapter 1: Introduction1-3NotesThe DOM Power connector (JWF1) and the Wake-On-Ring header (JWOR), 1. are supported by the PCB Rev. 2.01 or a newer ver

Page 4

1-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJumpers not indicated are for test purposes only. • " " indicates the location of

Page 5 - Contacting Supermicro

Chapter 1: Introduction1-5X8DTL-3/X8DTL-3F/ X8DTL-i/ X8DTL-iF Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear Open (Normal)JI2C1/JI2C

Page 6 - Table of Contents

1-6 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualMotherboard Features CPUTwo Intel• ® 5500/5600* Series (LGA 1366) processors, each processor

Page 7 - Chapter 3 Troubleshooting

Chapter 1: Introduction1-7ACPI Features Slow blinking LED for suspend state indicator• Main switch override mechanism• ACPI Power Management• Keyboard

Page 8 - Chapter 4 BIOS

1-8 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualBlock Diagram of the 5500 ChipsetNote: This is a general block diagram. Please see the previ

Page 9 - Introduction

Chapter 1: Introduction1-91-2 Chipset OverviewBuilt upon the functionality and the capability of the 5500 platform, the X8DTL-3/X8DTL-i/X8DTL-3F/X8D

Page 10

1-10 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual1-3 Special FeaturesRecovery from AC Power LossBIOS provides a setting for you to determi

Page 11 - Rev. 2.01

Chapter 1: Introduction1-11notify the user of certain system events. For example, you can also confi gure Supero Doctor to provide you with warnings wh

Page 12

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Page 13 - Chapter 1: Introduction

1-12 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualWOL capability. In addition, an onboard LAN controller can also support WOL without any con

Page 14 - (*Note 1 on P. 1-3.)

Chapter 1: Introduction1-13control capability and a processor interrupt system. Both UARTs provide legacy speed with baud rate of up to 115.2 Kbps as

Page 15

1-14 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualNotes

Page 16 - Intel 5500

Chapter 2: Installation2-1Chapter 2 Installation 2-1 Static-Sensitive DevicesElectrostatic Discharge (ESD) can damage electronic com ponents. To pre

Page 17 - 1-2 Chipset Overview

2-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualLocate the matching mounting holes on the chassis. Align the mounting holes 3. on

Page 18 - 1-4 PC Health Monitoring

Chapter 2: Installation2-32-3 Processor and Heatsink InstallationWhen handling the processor package, avoid placing direct pressure on the label are

Page 19 - 1-5 ACPI Features

2-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Socket KeysAfter removing the plastic cap, 1. using your thumb and the index fi ng

Page 20 - 1-7 Super I/O

Chapter 2: Installation2-5Installing a CPU HeatsinkScrew#1Screw#2Do not apply any thermal 1. grease to the heatsink or the CPU die because the require

Page 21 - X8DTL-3F/X8DTL-iF Only)

2-6 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualRemoving the HeatsinkWarning: We do not recommend that the CPU or the heatsink be

Page 22

Chapter 2: Installation2-7X8DTL SeriesRev. 2.012-4 Installing and Removing the Memory ModulesNote: Check the Supermicro web site for recommended mem

Page 23 - Installation

PrefaceAbout this ManualThis manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the inst

Page 24 - X8DTL Series

2-8 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualMemory SupportThe X8DTL-3/-i/-3F/iF supports up to 96 GB Registered ECC or up to 2

Page 25

Chapter 2: Installation2-9Memory Support for the Motherboard w/5600 Processors Installed1.5V Registered DIMMs (for the PCB R2.01 or a later version bo

Page 26

2-10 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualPossible System Memory Allocation & AvailabilitySystem Device Size Physical M

Page 27 - Installing a CPU Heatsink

Chapter 2: Installation2-11JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0

Page 28 - Removing the Heatsink

2-12 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and PS/2 mouse are lo

Page 29 - Release Tab

Chapter 2: Installation2-131. Backpanel USB 02. Backpanel USB 13. Front Panel USB 2/34. Front Panel USB 4/55. Front Panel USB 6Universal Serial Bus (U

Page 30 - Memory Support

2-14 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualSerial PortsTwo COM connections (COM1 & COM2) are located on the motherboard.

Page 31

Chapter 2: Installation2-151. LAN12. LAN23. LAN5 (X8DTL-3F/iF only)Ethernet PortsTwo Ethernet ports (LAN 1/LAN2) are located at on the IO backplane. I

Page 32

2-16 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual2. Front Control PanelJF1 contains header pins for various buttons and indicators

Page 33 - Back Panel Connectors

Chapter 2: Installation2-17Power ButtonOH/Fan Fail LED1NIC1 LEDReset Button2Power Fail LEDHDD LEDPower LEDResetPWRVccVccVccVcc/Front UID LEDGroundGrou

Page 34 - 2. Mouse (Green)

Danger/Caution: Instructions to be strictly followed to prevent catastrophic system failure or to avoid bodily injury.Warning: Important information g

Page 35

2-18 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualPower ButtonOH/Fan Fail LED1NIC1 LEDReset Button2Power Fail LEDHDD LEDPower LEDRe

Page 36

Chapter 2: Installation2-19Power ButtonOH/Fan Fail LED1NIC1 LEDReset Button2Power Fail LEDHDD LEDPower LEDResetPWRVccVccVccVcc/Front UID LEDGroundGrou

Page 37 - (NC: No Connection)

2-20 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualPower ButtonOH/Fan Fail LED1NIC1 LEDReset Button2Power Fail LEDHDD LEDPower LEDRe

Page 38 - 2. Front Control Panel

Chapter 2: Installation2-21JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0

Page 39

2-22 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP

Page 40

Chapter 2: Installation2-23JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0

Page 41

2-24 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP

Page 42

Chapter 2: Installation2-25JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0

Page 43 - 2-6 Connecting Cables

2-26 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP

Page 44

Chapter 2: Installation2-27JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0

Page 45

Contacting SupermicrovContacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408) 503-8

Page 46

2-28 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualWake-On-RingThe Wake-On-Ring header is desig-nated JWOR, which will allow your sy

Page 47

Chapter 2: Installation2-29JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0

Page 48

2-30 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP

Page 49

Chapter 2: Installation2-31JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0

Page 50

2-32 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP

Page 51 - 2-7 Jumper Settings

Chapter 2: Installation2-33JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0

Page 52

2-34 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP

Page 53

Chapter 2: Installation2-35JPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JPS2JOH1JPBJP5J16JD1CPU1 FANSlot3 PCI-E 1.0

Page 54

2-36 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualJPW3JPW2JBT1JPI2CCOM1I-SATA0I-ButtonJPS1JWDJPL2JPL1JF1SP11JWOLLE1D20JBAT1JP3JL1JP

Page 55 - IPMI LAN (F models only)

3-1Chapter 3: TroubleshootingChapter 3 Troubleshooting 3-1 Troubleshooting ProceduresUse the following procedures to troubleshoot your system. If you

Page 56

X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualviTable of ContentsPrefaceChapter 1 Introduction1-1 Overview ...

Page 57

3-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualUse the speaker to determine if any beep codes exist. Refer to the Appendix 2. for details on

Page 58

3-3Chapter 3: Troubleshootingusers, so it is best to fi rst check with your distributor or reseller for troubleshooting services. They should know of a

Page 59 - Troubleshooting

3-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manualwarning message and the information on how to update your BIOS on our web site. Select your mo

Page 60 - Memory Errors

Chapter 4: AMI BIOS4-1Chapter 4 BIOS 4-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF mot

Page 61 - • (http://www

4-2X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the m

Page 62

Chapter 4: AMI BIOS4-3Supermicro X8DTL-3/i/3F/iFVersion• : This item displays the BIOS revision used in your system.Build Date• : This item displays

Page 63 - Chapter 4

4-4X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual4-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter>

Page 64 - 4-2 Main Setup

Chapter 4: AMI BIOS4-5Hit 'Del' Message DisplayIf this feature is set to Enabled, the message: "Press DEL to run Setup" will be di

Page 65

4-6X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualRTC Alarm Time (Available if Resume on RTC Alarm is Enabled)Set the time when the system wakes

Page 66 - Boot Features

Chapter 4: AMI BIOS4-7L1 Data Prefetch (Available when supported by the CPU)Select Enabled to enable Level 1 data prefetch support to enhance system p

Page 67 - Power Confi guration

Table of ContentsviiReset Button ... 2-20Power Button ...

Page 68 - Processor and Clock Options

4-8X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualActive Processor CoresSet to Enabled to use a processor's Second Core and beyond. (Please

Page 69

Chapter 4: AMI BIOS4-9Advanced Chipset ControlCPU Bridge Confi gurationThis feature allows the user to confi gure CPU Bridge settings.CPU Revision• :

Page 70

4-10X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualMemory FrequencyThis feature forces a DDR3 memory module to run at a specifi c frequency. The a

Page 71 - CPU Bridge Confi guration

Chapter 4: AMI BIOS4-11DCA Prefetch DelayA DCA Prefetch is used with TOE components to prefetch data in order to shorten execution cycles and maximize

Page 72

4-12X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualUSB 2.0 Controller ModeThis setting allows you to select the USB 2.0 Controller mode. The opti

Page 73 - South Bridge Confi guration

Chapter 4: AMI BIOS4-13SATA#2 Confi guration (Available when the option "IDE" is selected)Selecting Enhanced will set SATA#2 to native SATA m

Page 74 - IDE/SATA Confi guration

4-14X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualPIO Mode Select OptionsOption Selected PIO Mode Max. Transfer Rate0 PIO Mode 0 3.3 MB/s1 PIO M

Page 75

Chapter 4: AMI BIOS4-15PCI/PnP Confi guration Clear NVRAMSelect Yes to clear the Non-Volatile Random Access (Flash) Memory (NVRAM) during system boot.

Page 76

4-16X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualLoad Onboard SAS Option ROM (Available when SAS is enabled on the X8DTL-3/-3F)Select Enabled t

Page 77 - PCI/PnP Confi guration

Chapter 4: AMI BIOS4-17Flow ControlThis feature allows the user to set the fl ow control for Console Redirection. The options are None, Hardware, and S

Page 78 - Remote Access Confi guration

X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualviiiNo Power ...

Page 79

4-18X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualThe Default Alarm• : Select this setting to trigger the CPU overheat alarm (in-cluding the LE

Page 80

Chapter 4: AMI BIOS4-19(i.e., by increasing CPU Fan speed, triggering the Overheat Alarm, etc). Since CPUs can have different ‘Temperature Tolerances’

Page 81

4-20X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualACPI Confi gurationUse this feature to confi gure Advanced Confi guration and Power Interface (A

Page 82 - ACPI Confi guration

Chapter 4: AMI BIOS4-21errors on Windows platforms in order to reduce system crashes due to hardware errors and to enhance system recovery and health

Page 83

4-22X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualIPMI Confi guration (For X8DTL-3F/iF only)Intelligent Platform Management Interface (IPMI) is

Page 84 - View BMC System Event Log

Chapter 4: AMI BIOS4-23Caution: Make sure that you no longer need any data stored in the event log before clearing the BMC Event Log because you will

Page 85 - Event Log Confi guration

4-24X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualMark all events as readSelect "OK" to mark all events as read. The options are OK an

Page 86 - 4-4 Security Settings

Chapter 4: AMI BIOS4-25Change Supervisor PasswordSelect this feature and press <Enter> to access the submenu, and then enter a new Supervisor Pa

Page 87 - 4-5 Boot Confi guration

4-26X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualBoot Device PriorityThis feature allows the user to specify the priority sequence of boot dev

Page 88

Chapter 4: AMI BIOS4-27Save Changes and ExitAfter confi guring the setup settings, select this option to save the changes and exit the BIOS Setup Utili

Page 89 - 4-6 Exit Options

Chapter 1: Introduction1-1Chapter 1 Introduction 1-1 OverviewChecklistCongratulations on purchasing your computer motherboard from an acknowledged lea

Page 90

4-28X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualNotes

Page 91 - BIOS Error Beep Codes

A-1Appendix A: BIOS POST Error CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Page 92

A-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualNotes

Page 93 - Appendix B

Appendix B: Software Installation InstructionsB-1Driver/Tool Installation Display ScreenNote 1. Click the icons showing a hand writing on the paper to

Page 94

B-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualSupero Doctor III Interface Display Screen-I (Health Information)B-2 Confi guring Supero Doctor

Page 95

Appendix B: Software Installation InstructionsB-3Supero Doctor III Interface Display Screen-II (Remote Control)Note: SD III Software Revision 1.0 can

Page 96

B-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's ManualNotes

Page 97

(Disclaimer Continued)The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear fa