SC847 Chassis Manual
4-14
Seven hot-swappable, heavy-duty fans provide cooling for the chassis. These fans
circulate air through the chassis thereby lowering the chassis internal tempera-
ture.
4-8 System Fans
Replacing a System Fan
Open the chassis while the power is running to determine which fan has 1.
failed. (Never run the server for an extended period of time with the chassis
cover open.)
Remove the failed fan's power cord from the serverboard.2.
Press the fan release tab to lift the failed fan from the chassis and pull it 3.
completely out of the chassis.
Place the new fan into the vacant space in the housing while making sure the 4.
arrows on the top of the fan (indicating airow direction) point in the same
direction as the arrows on the other fans.
Check that the fan is working properly before replacing the chassis cover.5.
Figure 4-14: System Fan
Release Tab
Airow
Direction
Indicator