6-15
Safety Information and Technical Speci cations
6-2 Adding Hotspare Disks
Hotspares are disk drives that are available to automatically replace failed drives
in a RAID 1, RAID 5, RAID 6 RAID 10, RAID 50, and RAID 60 virtual disk. Each
virtual disk can have one dedicated hotspare.
For more information, see the LSI documentation and software Help le for more
information.
To add a global hotspare disk, follow these steps:
1. In the left panel of the MegaRAID Storage Manager window, right click the icon
of any unused disk drive.
2. Select Make Global Hotspare.
For a RAID 10 array, the entire capacity of the array is automatically used for the
new virtual disk. You cannot defi ne another virtual disk on this array.
9. (Optional) Change the other Virtual Disk Properties, if necessary. For more
information, see Section , Understanding Virtual Disk Parameters.