AS 1040C-TAS 1040C-8 USER’S MANUAL1.0
xNotesAS1040C-T/1040C-8 User's Manual
B-8AS1040C-T/1040C-8 User's ManualNotes
C-1Appendix C: System Specifi cationsAppendix CSystem Specifi cationsProcessors Quad AMD Opteron™ 800 Series 64-bit processors in 940-pin micro PG
C-2AS1040C-T/1040C-8 User's ManualServerboard 1040C-T: H8QCE+ (Extended ATX form factor) 1040C-8: H8QC8+ (Extended ATX form factor)
C-3Appendix C: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR
C-4AS1040C-T/1040C-8 User's ManualNotes
Chapter 1 Introduction1-1 OverviewThe AS1040C-T/1040C-8 is a high-end quad processor server that is comprised of two main subsy
1-2AS1040C-T/1040C-8 User's Manual1-2 Serverboard FeaturesAt the heart of the 1040C-T/1040C-8 lies the H8QCE+/H8QC8+, a quad proces-sor serverboa
1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe 1040C-T/1040C-8 is a high-end, scaleable server platform. The following is a general outline
1-4AS1040C-T/1040C-8 User's ManualFront Control PanelThe control panel provides you with system monitoring and control. LEDs indicate system pow
1-5Chapter 1: IntroductionFigure 1-1. nVidia nForce Pro 2200/AMD 8132 Chipset: System Block DiagramNote: This is a general block diagram and may not
1-6AS1040C-T/1040C-8 User's ManualNotes
Chapter 2: Server Installation2-1 Chapter 2 Server Installation 2-1 OverviewThis chapter provides a quick setup checkl
2-2AS1040C-T/1040C-8 User's ManualChoosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front do
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
2-4AS1040C-T/1040C-8 User's Manual2-4 Installing the System into a RackThis section provides information on installing the system into a rack un
Chapter 2: Server Installation2-5Installing the Outer RailsBegin by measuring the distance from the front rail to the rear rail of the rack. Attach a
2-6AS1040C-T/1040C-8 User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have rails atta
Chapter 2: Server Installation2-72-5 Checking the Serverboard SetupAfter you install the 1040C-T/1040C-8 in the rack, you will need to open the unit
2-8AS1040C-T/1040C-8 User's ManualFigure 2-4. Accessing the Inside of the System
Chapter 2: Server Installation2-92-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the SATA/SCSI drives h
2-10AS1040C-T/1040C-8 User's ManualNotes
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SATA/S
3-2AS1040C-T/1040C-8 User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC818S+-1000 chassis has fi ve LEDs. These
Chapter 3: System Interface3-3 HDD: Indicates IDE channel activity. On the 1040C-T/1040C-8, this light indicates SATA/SCSI and/or DVD-ROM drive ac
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation a
3-4AS1040C-T/1040C-8 User's ManualNotes
Chapter 4: System Safety4-1 Chapter 4 System Safety!Basic electrical safety precautions should be followed to protect yourself from
AS1040C-T/1040C-8 User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety: Keep the area around the 1040C-T
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into
AS1040C-T/1040C-8 User's Manual4-44-4 Operating Precautions Care must be taken to assure that the chassis cover is in place when the 104
Chapter 5: Advanced Serverboard Setup5-1 Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install pro
5-2AS1040C-T/1040C-8 User's Manual5-2 Mounting the Serverboard into a ChassisAll serverboards and motherboards have standard mounting holes to fi
Chapter 5: Advanced Serverboard Setup5-35-3 Processor and Heatsink Installation!Installing the Processor (must populate all four CPU sockets) 1. Lift
5-4AS1040C-T/1040C-8 User's ManualInstalling the HeatsinksTo install the heatsink (SNK-P0012, optional), do not apply any thermal compound to the
Chapter 5: Advanced Serverboard Setup5-5Figure 5-1. CPU Backplate/Heatsink Retention Module Installation
ivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be fo
5-6AS1040C-T/1040C-8 User's Manual5-4 Connecting CablesNow that the processors are installed, the next step is to connect the cables to the serv
Chapter 5: Advanced Serverboard Setup5-7Figure 5-2. Front Control Panel Header Pins (JF1)NCx (key)VccVccVccVccVccVccReset ButtonPower ButtonNCx (key)P
5-8AS1040C-T/1040C-8 User's Manual5-6 Installing MemoryCAUTIONExercise extreme care when installing or removing memory modules to prevent any pos
Chapter 5: Advanced Serverboard Setup5-9Figure 5-4. Side and Top Views of DDR InstallationTo Install: Insert module vertically and press down until i
5-10AS1040C-T/1040C-8 User's Manual5-8 Serverboard DetailsFigure 5-5. H8QC8+/H8QCE+ Serverboard Layout (not drawn to scale)Notes: Jumpers not i
Chapter 5: Advanced Serverboard Setup5-11H8QC8+/H8QCE+ Quick Reference Jumpers Description Default Setting J3P 3rd Power Fail Detect Op
5-12AS1040C-T/1040C-8 User's Manual5-9 Connector Defi nitions ATX Power ConnectorThe primary ATX power supply con-nector (J1B1) meets the SSI (Sup
Chapter 5: Advanced Serverboard Setup5-13Overheat/Fan Fail LEDConnect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced warning
5-14AS1040C-T/1040C-8 User's ManualPower Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the rig
Chapter 5: Advanced Serverboard Setup5-15Fan HeadersThe serverboard has nine fan head-ers, which are designated FAN1 through FAN9. Fans speed may be
vPrefaceNotes
5-16AS1040C-T/1040C-8 User's ManualATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse ports are located at J3. The m
Chapter 5: Advanced Serverboard Setup5-17Wake-On-LANThe Wake-On-LAN header is desig-nated JWOL. See the table on the right for pin defi nitions. You
5-18AS1040C-T/1040C-8 User's ManualI2C Header for Power SupplyThe I2C header at J16 may be used to monitor the power supply. See the table on th
Chapter 5: Advanced Serverboard Setup5-19CMOS ClearJBT1 is used to clear CMOS and will also clear any passwords. Instead of pins, this jumper consist
5-20AS1040C-T/1040C-8 User's ManualSCSI Controller Enable/Disable (1040C-8 only)Jumper JPA1 is used to enable or dis-able the Adaptec AIC-7902W S
Chapter 5: Advanced Serverboard Setup5-21Watch Dog Enable/DisableJWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot t
5-22AS1040C-T/1040C-8 User's Manual5-11 Onboard Indicators JLAN1/JLAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. O
Chapter 5: Advanced Serverboard Setup5-23Floppy Drive ConnectorPin Defi nitions (Floppy)Pin# Defi nition Pin # Defi nition1 GND
5-24AS1040C-T/1040C-8 User's ManualIDE ConnectorsThere are no jumpers to confi g-ure the onboard IDE#1 and #2 connectors. See the table on the ri
Chapter 5: Advanced Serverboard Setup5-25SATA PortsThere are no jumpers to con-fi gure the SATA ports, which are designated SATA0-SATA3. See the table
viTable of ContentsPrefaceAbout This Manual ... ii
5-26AS1040C-T/1040C-8 User's ManualUltra320 SCSI Drive ConnectorsPin Defi nitions (JA1/JB1)Pin# Defi nition Pin # Defi nit
Chapter 5: Advanced Serverboard Setup5-275-13 Enabling SATA RAIDSerial ATA (SATA)Serial ATA (SATA) is a physical storage interface that employs a sin
5-28AS1040C-T/1040C-8 User's Manual2. Use the arrow keys to move to the "Advanced" menu, then scroll down to "IDE Confi guration&qu
Chapter 6: Advanced Chassis Setup6-1Chapter 6Advanced Chassis Setup This chapter covers the steps required to install components and perform m
6-2AS1040C-T/1040C-8 User's ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the front of the chass
Chapter 6: Advanced Chassis Setup6-36-3 System FansSix 4-cm fans provide the cooling for the 1040C-T/1040C-8. Each fan unit is actually made up of tw
6-4AS1040C-T/1040C-8 User's Manual6-4 Drive Bay Installation/RemovalAccessing the Drive BaysSATA/SCSI Drives: Because of their hotswap capability
Chapter 6: Advanced Chassis Setup6-5SATA/SCSI Drive Installation1. Mounting a SATA/SCSI drive in a drive carrier The SATA/SCSI drives are mounted i
6-6AS1040C-T/1040C-8 User's Manual2. Installing/removing SATA/SCSI drivesThe SATA/SCSI drive carriers are all easily accessible at the front of t
Chapter 6: Advanced Chassis Setup6-7DVD-ROM and Floppy Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-RO
Chapter 4: System Safety 4-1 Electrical Safety Precautions ... 4-14-2 Gene
6-8AS1040C-T/1040C-8 User's Manual6-5 Power SupplyThe AS1040C-T/1040C-8 has a single 1000 watt power supply, which is auto-switch-ing capable. T
Chapter 6: Advanced Chassis Setup6-9Figure 6-6. Removing/Replacing the Power Supply
6-10AS1040C-T/1040C-8 User's ManualNotes
Chapter 7: BIOS7-1 Chapter 7 BIOS7-1 IntroductionThis chapter describes the AMIBIOS™ Setup utility for t
7-2AS1040C-T/1040C-8 User's Manual7-2 Main MenuWhen you fi rst enter AMI BIOS Setup Utility, you will see the Main Menu screen. You can always ret
Chapter 7: BIOS7-3Primary/Secondary IDE Master/SlaveHighlight one of the items above and press <Enter> to access the submenu for that item.
7-4AS1040C-T/1040C-8 User's Manualdata transfer rate of 3.3 MBs. Select 1 to allow AMI BIOS to use PIO mode 1 for a data transfer rate of 5.2 MBs
Chapter 7: BIOS7-5ATA(PI) 80Pin Cable DetectionThis setting allows AMI BIOS to auto-detect the 80-Pin ATA(PI) cable. The options are Host, Device and
7-6AS1040C-T/1040C-8 User's Manual PCI/PnP Confi guration Clear NVRAMSelect Yes to clear NVRAM during boot-up. The options are Yes and No.Plug
Chapter 7: BIOS7-7Available and Reserved.DMA Channel0/Channel1/Channel3/Channel5/Channel6/Channel7Select Available to indicate that a specifi c DMA cha
viiiChassis Intrusion ... 5-16Wake-On-LAN ...
7-8AS1040C-T/1040C-8 User's Manualports on computer systems use IRQ7 and I/O Port 378H as the standard setting. Select 278 to allow the parallel
Chapter 7: BIOS7-9Hardware Memory HoleWhen "Enabled", allows software memory remapping around the memory hole. Options are Enabled and Disa
7-10AS1040C-T/1040C-8 User's ManualData Cache BG ScrubAllows L1 cache RAM to be corrected when idle. Options are Disabled and various times in n
Chapter 7: BIOS7-11 ACPI Confi guration Advanced ACPI Confi gurationACPI 2.0 Features"Yes" enables RSDP pointers to 64-bit fi xed system de
7-12AS1040C-T/1040C-8 User's Manual Hyper Transport Confi gurationCPU0: CPU1 HT Link SpeedThe HT link will run at the speed specifi ed in this se
Chapter 7: BIOS7-13 PCI Express Confi guration Active State Power ManagementUse this setting to Enable or Disable PCI Express L0s and L1 link power
7-14AS1040C-T/1040C-8 User's Manual System Health MonitorCPU Overheat TemperatureUse the "+" and "-" keys to set the CPU te
Chapter 7: BIOS7-157-4 Boot MenuThis feature allows the user to confi gure the following items: Boot Settings Confi guration Quick BootIf Enabled, thi
7-16AS1040C-T/1040C-8 User's Manual Boot Device PriorityThis feature allows the user to prioritize the sequence for the Boot Device. The devic
Chapter 7: BIOS7-177-5 Security MenuAMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set
Table of ContentsixChapter 7: BIOS 7-1 Introduction ...
7-18AS1040C-T/1040C-8 User's ManualLoad Optimal DefaultsTo set this feature, select Load Optimal Defaults from the Exit menu and press <Enter&
Appendix A BIOS Error Beep CodesDuring the POST (Power-On Self-Test) routines, which are performed each time the system is powered on
A-2AS1040C-T/1040C-8 User's ManualNotes
B-1Appendix B: BIOS POST Checkpoint Codes Appendix B BIOS POST Checkpoint CodesWhen AMIBIOS performs the Power On
B-2AS1040C-T/1040C-8 User's ManualCheckpoint Code Description E0h The onboard fl oppy controller if available is initialized. Next, beginn
B-3Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description 03h The NMI is disabled. Next, checking for a soft reset or a power on co
B-4AS1040C-T/1040C-8 User's ManualCheckpoint Code Description 25h Interrupt vector initialization is done. Clearing the password if the P
B-5Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description 4Ch The memory below 1 MB has been cleared via a soft reset. Clearing the
B-6AS1040C-T/1040C-8 User's ManualCheckpoint Code Description 86h The password was checked. Performing any required programming before WI
B-7Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description A9h Returned from adaptor ROM at E000h control. Performing any initializa