AS 1040C-TAS 1040C-8 USER’S MANUAL1.0

Page 2 - Manual Revision 1.0

xNotesAS1040C-T/1040C-8 User's Manual

Page 3 - Manual Organization

B-8AS1040C-T/1040C-8 User's ManualNotes

Page 4

C-1Appendix C: System Specifi cationsAppendix CSystem Specifi cationsProcessors Quad AMD Opteron™ 800 Series 64-bit processors in 940-pin micro PG

Page 5

C-2AS1040C-T/1040C-8 User's ManualServerboard 1040C-T: H8QCE+ (Extended ATX form factor) 1040C-8: H8QC8+ (Extended ATX form factor)

Page 6 - Table of Contents

C-3Appendix C: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR

Page 7 - Chapter 4: System Safety

C-4AS1040C-T/1040C-8 User's ManualNotes

Page 8

Chapter 1 Introduction1-1 OverviewThe AS1040C-T/1040C-8 is a high-end quad processor server that is comprised of two main subsy

Page 9 - Appendices:

1-2AS1040C-T/1040C-8 User's Manual1-2 Serverboard FeaturesAt the heart of the 1040C-T/1040C-8 lies the H8QCE+/H8QC8+, a quad proces-sor serverboa

Page 10

1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe 1040C-T/1040C-8 is a high-end, scaleable server platform. The following is a general outline

Page 11 - Introduction

1-4AS1040C-T/1040C-8 User's ManualFront Control PanelThe control panel provides you with system monitoring and control. LEDs indicate system pow

Page 12 - 1-2 Serverboard Features

1-5Chapter 1: IntroductionFigure 1-1. nVidia nForce Pro 2200/AMD 8132 Chipset: System Block DiagramNote: This is a general block diagram and may not

Page 13 - 1-3 Server Chassis Features

1-6AS1040C-T/1040C-8 User's ManualNotes

Page 14 - I/O Backplane

Chapter 2: Server Installation2-1 Chapter 2 Server Installation 2-1 OverviewThis chapter provides a quick setup checkl

Page 15 - (CK804 )

2-2AS1040C-T/1040C-8 User's ManualChoosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front do

Page 16

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Page 17 - Chapter 2

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Page 18 - Warnings and Precautions!

2-4AS1040C-T/1040C-8 User's Manual2-4 Installing the System into a RackThis section provides information on installing the system into a rack un

Page 19 - Rack Mounting Considerations

Chapter 2: Server Installation2-5Installing the Outer RailsBegin by measuring the distance from the front rail to the rear rail of the rack. Attach a

Page 20 - Installing the Inner Rails

2-6AS1040C-T/1040C-8 User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have rails atta

Page 21 - Installing the Outer Rails

Chapter 2: Server Installation2-72-5 Checking the Serverboard SetupAfter you install the 1040C-T/1040C-8 in the rack, you will need to open the unit

Page 22

2-8AS1040C-T/1040C-8 User's ManualFigure 2-4. Accessing the Inside of the System

Page 23

Chapter 2: Server Installation2-92-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the SATA/SCSI drives h

Page 24

2-10AS1040C-T/1040C-8 User's ManualNotes

Page 25

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SATA/S

Page 26

3-2AS1040C-T/1040C-8 User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC818S+-1000 chassis has fi ve LEDs. These

Page 27 - System Interface

Chapter 3: System Interface3-3 HDD: Indicates IDE channel activity. On the 1040C-T/1040C-8, this light indicates SATA/SCSI and/or DVD-ROM drive ac

Page 28 - 3-3 Control Panel LEDs

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation a

Page 29 - 3-4 Drive Carrier LEDs

3-4AS1040C-T/1040C-8 User's ManualNotes

Page 30

Chapter 4: System Safety4-1 Chapter 4 System Safety!Basic electrical safety precautions should be followed to protect yourself from

Page 31 - System Safety

AS1040C-T/1040C-8 User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:  Keep the area around the 1040C-T

Page 32

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Page 33 - 4-3 ESD Precautions

AS1040C-T/1040C-8 User's Manual4-44-4 Operating Precautions Care must be taken to assure that the chassis cover is in place when the 104

Page 34 - 4-4 Operating Precautions

Chapter 5: Advanced Serverboard Setup5-1 Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install pro

Page 35 - Advanced Serverboard Setup

5-2AS1040C-T/1040C-8 User's Manual5-2 Mounting the Serverboard into a ChassisAll serverboards and motherboards have standard mounting holes to fi

Page 36

Chapter 5: Advanced Serverboard Setup5-35-3 Processor and Heatsink Installation!Installing the Processor (must populate all four CPU sockets) 1. Lift

Page 37 - Triangles

5-4AS1040C-T/1040C-8 User's ManualInstalling the HeatsinksTo install the heatsink (SNK-P0012, optional), do not apply any thermal compound to the

Page 38 - Installing the Heatsinks

Chapter 5: Advanced Serverboard Setup5-5Figure 5-1. CPU Backplate/Heatsink Retention Module Installation

Page 39

ivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be fo

Page 40 - 5-4 Connecting Cables

5-6AS1040C-T/1040C-8 User's Manual5-4 Connecting CablesNow that the processors are installed, the next step is to connect the cables to the serv

Page 41 - 5-5 I/O Ports

Chapter 5: Advanced Serverboard Setup5-7Figure 5-2. Front Control Panel Header Pins (JF1)NCx (key)VccVccVccVccVccVccReset ButtonPower ButtonNCx (key)P

Page 42 - 5-6 Installing Memory

5-8AS1040C-T/1040C-8 User's Manual5-6 Installing MemoryCAUTIONExercise extreme care when installing or removing memory modules to prevent any pos

Page 43 - 5-7 Adding PCI Cards

Chapter 5: Advanced Serverboard Setup5-9Figure 5-4. Side and Top Views of DDR InstallationTo Install: Insert module vertically and press down until i

Page 44 - 5-8 Serverboard Details

5-10AS1040C-T/1040C-8 User's Manual5-8 Serverboard DetailsFigure 5-5. H8QC8+/H8QCE+ Serverboard Layout (not drawn to scale)Notes: Jumpers not i

Page 45 - Connectors Description

Chapter 5: Advanced Serverboard Setup5-11H8QC8+/H8QCE+ Quick Reference Jumpers Description Default Setting J3P 3rd Power Fail Detect Op

Page 46 - 5-9 Connector Defi nitions

5-12AS1040C-T/1040C-8 User's Manual5-9 Connector Defi nitions ATX Power ConnectorThe primary ATX power supply con-nector (J1B1) meets the SSI (Sup

Page 47 - NIC2 LED

Chapter 5: Advanced Serverboard Setup5-13Overheat/Fan Fail LEDConnect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced warning

Page 48

5-14AS1040C-T/1040C-8 User's ManualPower Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the rig

Page 49 - Extra USB Headers

Chapter 5: Advanced Serverboard Setup5-15Fan HeadersThe serverboard has nine fan head-ers, which are designated FAN1 through FAN9. Fans speed may be

Page 51

5-16AS1040C-T/1040C-8 User's ManualATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse ports are located at J3. The m

Page 52

Chapter 5: Advanced Serverboard Setup5-17Wake-On-LANThe Wake-On-LAN header is desig-nated JWOL. See the table on the right for pin defi nitions. You

Page 53 - 5-10 Jumper Settings

5-18AS1040C-T/1040C-8 User's ManualI2C Header for Power SupplyThe I2C header at J16 may be used to monitor the power supply. See the table on th

Page 54

Chapter 5: Advanced Serverboard Setup5-19CMOS ClearJBT1 is used to clear CMOS and will also clear any passwords. Instead of pins, this jumper consist

Page 55 - VGA Enable/Disable

5-20AS1040C-T/1040C-8 User's ManualSCSI Controller Enable/Disable (1040C-8 only)Jumper JPA1 is used to enable or dis-able the Adaptec AIC-7902W S

Page 56 - 5-11 Onboard Indicators

Chapter 5: Advanced Serverboard Setup5-21Watch Dog Enable/DisableJWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot t

Page 57 - Connections

5-22AS1040C-T/1040C-8 User's Manual5-11 Onboard Indicators JLAN1/JLAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. O

Page 58 - IDE Connectors

Chapter 5: Advanced Serverboard Setup5-23Floppy Drive ConnectorPin Defi nitions (Floppy)Pin# Defi nition Pin # Defi nition1 GND

Page 59 - Connector

5-24AS1040C-T/1040C-8 User's ManualIDE ConnectorsThere are no jumpers to confi g-ure the onboard IDE#1 and #2 connectors. See the table on the ri

Page 60 - (1040C-8 only)

Chapter 5: Advanced Serverboard Setup5-25SATA PortsThere are no jumpers to con-fi gure the SATA ports, which are designated SATA0-SATA3. See the table

Page 61 - 5-13 Enabling SATA RAID

viTable of ContentsPrefaceAbout This Manual ... ii

Page 62 - Installing the OS and Drivers

5-26AS1040C-T/1040C-8 User's ManualUltra320 SCSI Drive ConnectorsPin Defi nitions (JA1/JB1)Pin# Defi nition Pin # Defi nit

Page 63 - Advanced Chassis Setup

Chapter 5: Advanced Serverboard Setup5-275-13 Enabling SATA RAIDSerial ATA (SATA)Serial ATA (SATA) is a physical storage interface that employs a sin

Page 64 - 6-2 Control Panel

5-28AS1040C-T/1040C-8 User's Manual2. Use the arrow keys to move to the "Advanced" menu, then scroll down to "IDE Confi guration&qu

Page 65 - 6-3 System Fans

Chapter 6: Advanced Chassis Setup6-1Chapter 6Advanced Chassis Setup This chapter covers the steps required to install components and perform m

Page 66 - Accessing the Drive Bays

6-2AS1040C-T/1040C-8 User's ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the front of the chass

Page 67 - SATA/SCSI Drive Installation

Chapter 6: Advanced Chassis Setup6-36-3 System FansSix 4-cm fans provide the cooling for the 1040C-T/1040C-8. Each fan unit is actually made up of tw

Page 68

6-4AS1040C-T/1040C-8 User's Manual6-4 Drive Bay Installation/RemovalAccessing the Drive BaysSATA/SCSI Drives: Because of their hotswap capability

Page 69

Chapter 6: Advanced Chassis Setup6-5SATA/SCSI Drive Installation1. Mounting a SATA/SCSI drive in a drive carrier The SATA/SCSI drives are mounted i

Page 70 - 6-5 Power Supply

6-6AS1040C-T/1040C-8 User's Manual2. Installing/removing SATA/SCSI drivesThe SATA/SCSI drive carriers are all easily accessible at the front of t

Page 71

Chapter 6: Advanced Chassis Setup6-7DVD-ROM and Floppy Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-RO

Page 72

Chapter 4: System Safety 4-1 Electrical Safety Precautions ... 4-14-2 Gene

Page 73 - 7-1 Introduction

6-8AS1040C-T/1040C-8 User's Manual6-5 Power SupplyThe AS1040C-T/1040C-8 has a single 1000 watt power supply, which is auto-switch-ing capable. T

Page 74 - 7-3 Advanced Settings Menu

Chapter 6: Advanced Chassis Setup6-9Figure 6-6. Removing/Replacing the Power Supply

Page 75

6-10AS1040C-T/1040C-8 User's ManualNotes

Page 76

Chapter 7: BIOS7-1 Chapter 7 BIOS7-1 IntroductionThis chapter describes the AMIBIOS™ Setup utility for t

Page 77 - Floppy Confi guration

7-2AS1040C-T/1040C-8 User's Manual7-2 Main MenuWhen you fi rst enter AMI BIOS Setup Utility, you will see the Main Menu screen. You can always ret

Page 78 - PCI/PnP Confi guration

Chapter 7: BIOS7-3Primary/Secondary IDE Master/SlaveHighlight one of the items above and press <Enter> to access the submenu for that item.

Page 79 - Super IO Confi guration

7-4AS1040C-T/1040C-8 User's Manualdata transfer rate of 3.3 MBs. Select 1 to allow AMI BIOS to use PIO mode 1 for a data transfer rate of 5.2 MBs

Page 80 - Chipset Menu

Chapter 7: BIOS7-5ATA(PI) 80Pin Cable DetectionThis setting allows AMI BIOS to auto-detect the 80-Pin ATA(PI) cable. The options are Host, Device and

Page 81

7-6AS1040C-T/1040C-8 User's Manual PCI/PnP Confi guration Clear NVRAMSelect Yes to clear NVRAM during boot-up. The options are Yes and No.Plug

Page 82 - South Bridge Confi guration

Chapter 7: BIOS7-7Available and Reserved.DMA Channel0/Channel1/Channel3/Channel5/Channel6/Channel7Select Available to indicate that a specifi c DMA cha

Page 83 - Power Menu

viiiChassis Intrusion ... 5-16Wake-On-LAN ...

Page 84 -  MPS Confi guration

7-8AS1040C-T/1040C-8 User's Manualports on computer systems use IRQ7 and I/O Port 378H as the standard setting. Select 278 to allow the parallel

Page 85

Chapter 7: BIOS7-9Hardware Memory HoleWhen "Enabled", allows software memory remapping around the memory hole. Options are Enabled and Disa

Page 86 - System Fan Monitor

7-10AS1040C-T/1040C-8 User's ManualData Cache BG ScrubAllows L1 cache RAM to be corrected when idle. Options are Disabled and various times in n

Page 87 - 7-4 Boot Menu

Chapter 7: BIOS7-11 ACPI Confi guration Advanced ACPI Confi gurationACPI 2.0 Features"Yes" enables RSDP pointers to 64-bit fi xed system de

Page 88 - Removable Drives

7-12AS1040C-T/1040C-8 User's Manual Hyper Transport Confi gurationCPU0: CPU1 HT Link SpeedThe HT link will run at the speed specifi ed in this se

Page 89 - 7-6 Exit Menu

Chapter 7: BIOS7-13 PCI Express Confi guration Active State Power ManagementUse this setting to Enable or Disable PCI Express L0s and L1 link power

Page 90 - Load Fail-Safe Defaults

7-14AS1040C-T/1040C-8 User's Manual System Health MonitorCPU Overheat TemperatureUse the "+" and "-" keys to set the CPU te

Page 91 - BIOS Error Beep Codes

Chapter 7: BIOS7-157-4 Boot MenuThis feature allows the user to confi gure the following items: Boot Settings Confi guration Quick BootIf Enabled, thi

Page 92

7-16AS1040C-T/1040C-8 User's Manual Boot Device PriorityThis feature allows the user to prioritize the sequence for the Boot Device. The devic

Page 93 - Appendix B

Chapter 7: BIOS7-177-5 Security MenuAMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set

Page 94 - B-2 Bootblock Recovery Codes

Table of ContentsixChapter 7: BIOS 7-1 Introduction ...

Page 95

7-18AS1040C-T/1040C-8 User's ManualLoad Optimal DefaultsTo set this feature, select Load Optimal Defaults from the Exit menu and press <Enter&

Page 96

Appendix A BIOS Error Beep CodesDuring the POST (Power-On Self-Test) routines, which are performed each time the system is powered on

Page 97

A-2AS1040C-T/1040C-8 User's ManualNotes

Page 98

B-1Appendix B: BIOS POST Checkpoint Codes Appendix B BIOS POST Checkpoint CodesWhen AMIBIOS performs the Power On

Page 99

B-2AS1040C-T/1040C-8 User's ManualCheckpoint Code Description E0h The onboard fl oppy controller if available is initialized. Next, beginn

Page 100

B-3Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description 03h The NMI is disabled. Next, checking for a soft reset or a power on co

Page 101 - System Specifi cations

B-4AS1040C-T/1040C-8 User's ManualCheckpoint Code Description 25h Interrupt vector initialization is done. Clearing the password if the P

Page 102

B-5Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description 4Ch The memory below 1 MB has been cleared via a soft reset. Clearing the

Page 103 - Regulatory Compliance

B-6AS1040C-T/1040C-8 User's ManualCheckpoint Code Description 86h The password was checked. Performing any required programming before WI

Page 104

B-7Appendix B: BIOS POST Checkpoint CodesCheckpoint Code Description A9h Returned from adaptor ROM at E000h control. Performing any initializa