Résumé du contenu

Page 1 - SUPER

SUPERSERVER5018D-MF SUPER®USER’S MANUAL1.0

Page 2 - Release Date: June 25, 2013

1-2SUPERSERVER 5018D-MF User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 5018D-MF lies the X10SLL-F, a single processor mothe

Page 3 - Manual Organization

7-18SUPERSERVER 5018D-MF User's Manualment) to boot the computer using a PXE device installed in a LAN port specifi ed. Select Disabled to prevent

Page 4

Chapter 7: BIOS7-19• SPS Version• ME FW (Firmware) Status Value• ME FW State• ME FW Operation State• ME FW Error Code• ME NM FW Status Value• BIOS Boo

Page 5

7-20SUPERSERVER 5018D-MF User's ManualSOL Change SettingsThis feature specifi es the base I/O port address and the Interrupt Request ad-dress of S

Page 6 - Table of Contents

Chapter 7: BIOS7-21Stop BitsA stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 S

Page 7

7-22SUPERSERVER 5018D-MF User's ManualConsole Redirection (for EMS)Select Enabled to use a COM Port selected by the user for Console Redirection.

Page 8

Chapter 7: BIOS7-237-4 Event LogsChange SMBIOS Event Log SettingsEnabling/Disabling OptionsSMBIOS Event LogChange this item to enable or disable all

Page 9 - Introduction

7-24SUPERSERVER 5018D-MF User's ManualSMBIOS Event Long Standard SettingsLog System Boot EventThis option toggles the System Boot Event logging t

Page 10 - 1-2 Motherboard Features

Chapter 7: BIOS7-25IPMIThe following IPMI information will be displayed:• IPMI Firmware Revision• IPMI StatusSystem Event LogThis feature is used to

Page 11 - 1-3 Server Chassis Features

7-26SUPERSERVER 5018D-MF User's ManualBMC Network Confi gurationLAN Channel 1: This feature allows the user to confi gure the settings for LAN1 Po

Page 12 - System Block Diagram

Chapter 7: BIOS7-277-5 Boot SettingsUse this feature to confi gure Boot Settings:Set Boot PriorityThis option prioritizes the order of bootable devices

Page 13 - 1-4 Contacting Supermicro

1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe SC512F-350B is a short depth (14.5") 1U rackmount server chassis. The fol-lowing is a g

Page 14

7-28SUPERSERVER 5018D-MF User's ManualDelete Boot OptionThis feature allows the user to delete a previously defi ned boot device from which the

Page 15 - Server Installation

Chapter 7: BIOS7-297-6 Security SettingsThis menu allows the user to confi gure the following security settings for the system.• If the Administrator

Page 16 - 2-4 Warnings and Precautions

7-30SUPERSERVER 5018D-MF User's Manual7-7 Save & ExitSelect the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS Setup scr

Page 17 - Rack Mounting Considerations

Chapter 7: BIOS7-31Restore Optimized DefaultsTo set this feature, select Restore Defaults from the Exit menu and press <Enter>. These are factor

Page 18 - Basic Installation Procedure

7-32SUPERSERVER 5018D-MF User's ManualNotes

Page 19 - Installing with Rackmount Kit

Appendix A: BIOS Error Beep CodesA-1BIOS Error Beep CodesBeep Code/LED Error Message Description1 beep Refresh Circuits have been reset. (Ready to pow

Page 20

A-2SUPERSERVER 5018D-MF User's ManualNotes

Page 21

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsSingle Intel® Core™ i7/i5/i3 DT or Intel® Xeon® E3-1200 v3 or Intel® Xeo

Page 22

B-2SUPERSERVER 5018D-MF User's ManualWeightGross Weight: 18 lbs. (8.2 kg.)System CoolingTwo 4-cm counter-rotating fansSystem Input RequirementsAC

Page 23 - System Interface

B-3Appendix B: System Specifi cationsDisclaimer (continued from front)The products sold by Supermicro are not intended for and will not be used in life

Page 24 - 3-3 Control Panel LEDs

1-4SUPERSERVER 5018D-MF User's ManualFigure 1-1. Intel C222 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapt

Page 25 - Chapter 3: System Interface

B-4SUPERSERVER 5018D-MF User's ManualNotes

Page 26

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408

Page 27 - Chapter 4

1-6SUPERSERVER 5018D-MF User's ManualNotes

Page 28

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 5018D-

Page 29 - ﺔﻴﺋﺎﺑﺮﻬﻜﻟﺍ

2-2SUPERSERVER 5018D-MF User's ManualChoosing a Setup Location• Leave enough clearance in front of the rack to enable you to open the front door

Page 30 - Installation Instructions

Chapter 2: Server Installation2-3• Always keep the rack's front door and all panels and components on the servers closed when not servicing to ma

Page 31 - 250 V, 20 A

2-4SUPERSERVER 5018D-MF User's Manual2-5 Installing the System into a RackThis section provides information on installing the SuperServer 5018D-

Page 32 - Power Disconnection Warning

Chapter 2: Server Installation2-5Installing with Rackmount KitThis is a guideline for installing the unit into a rack with the optional rack kit (MCP-

Page 33 - ילמשח קותינ ינפמ הרהזא

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Page 34 - Equipment Installation

2-6SUPERSERVER 5018D-MF User's ManualInstalling the Rack Rails1. Determine where you want to place the 5018D-MF in the rack (see Rack and Server

Page 35 - Restricted Area

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Rack(w/ Optional Rackmount Kit)Note: Figure is for illustrative purposes onl

Page 36 - Battery Handling

2-8SUPERSERVER 5018D-MF User's ManualFigure 2-4. Installing the Server into a Telco RackInstalling the Server into a Telco RackIf you are install

Page 37

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel to keep you constantly informed of the

Page 38 - Redundant Power Supplies

3-2SUPERSERVER 5018D-MF User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC512F-520B chassis has fi ve LEDs. Thes

Page 39 - Backplane Voltage

Chapter 3: System Interface3-3HDDChannel activity for HDDs. This light indicates IDE drive activity when fl ashing.PowerIndicates power is being suppli

Page 40

3-4SUPERSERVER 5018D-MF User's ManualNotes

Page 41 - Product Disposal

4-1Chapter 4: Warning Statements for AC SystemsChapter 4Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe fo

Page 42 - רצומה קוליס

4-2SUPERSERVER 5018D-MF User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation,

Page 43

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확

Page 44 - Power Cable and AC Adapter

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Page 45 - (UL/CSA ﻞﻤﺤﺗ ﻲﺘﻟﺍﺔﻣﻼﻋ )

4-4SUPERSERVER 5018D-MF User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the system to the pow

Page 46

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Page 47 - Advanced Motherboard Setup

4-6SUPERSERVER 5018D-MF User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソースから切断され、電源コードは

Page 48

4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu

Page 49 - CPU Pin 1

4-8SUPERSERVER 5018D-MF User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained and qualifi ed

Page 50 - Removing the Heatsink

4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユ ニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Th

Page 51

4-10SUPERSERVER 5018D-MF User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly. Replace t

Page 52

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Page 53 - • SATA cable (I-SATA0)

4-12SUPERSERVER 5018D-MF User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom z

Page 54 - 5-4 I/O Ports

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能

Page 55 - 5-5 Installing Memory

SUPERSERVER 5018D-MF User's ManualivChapter 4: Standardized Warning StatementsYou should thoroughly familiarize yourself with this chapter for a

Page 56

4-14SUPERSERVER 5018D-MF User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must comply with loca

Page 57

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Page 58 - 5-6 Adding PCI Cards

4-16SUPERSERVER 5018D-MF User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle

Page 59 - 5-7 Motherboard Details

4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt

Page 60

4-18SUPERSERVER 5018D-MF User's Manual Warning!When installing the product, use the provided or designated connection cables, power cables and AC

Page 61 - 5-8 Connector Defi nitions

4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné

Page 62

4-20SUPERSERVER 5018D-MF User's ManualNotes

Page 63

Chapter 5: Advanced Motherboard Setup5-1Chapter 5 Advanced Motherboard SetupThis chapter covers the steps required to install processors and heatsinks

Page 64

5-2SUPERSERVER 5018D-MF User's Manual5-2 Processor and Heatsink InstallationNotes: • Always connect the power cord last and always remove it bef

Page 65

Chapter 5: Advanced Motherboard Setup5-35. Align the CPU key, which is a semi-circle cutout, against the socket key, which is the notch below the gol

Page 66

vPrefaceNotes

Page 67 - 5-9 Jumper Settings

5-4SUPERSERVER 5018D-MF User's ManualInstalling a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the CPU die; the req

Page 68

Chapter 5: Advanced Motherboard Setup5-5Figure 5-1. Installing the HeatsinkFigure 5-2. Removing the HeatsinkScrew #1MotherboardLoosen screws in the se

Page 69

5-6SUPERSERVER 5018D-MF User's ManualFigure 5-1. Installing the HeatsinkFigure 5-2. Removing the HeatsinkScrew #1MotherboardLoosen screws in the

Page 70 - 5-10 Onboard Indicators

Chapter 5: Advanced Motherboard Setup5-75-3 Connecting CablesNow that the processors are installed, the next step is to connect the cables to the moth

Page 71 - 5-11 SATA Drive Connections

5-8SUPERSERVER 5018D-MF User's ManualFigure 5-1. Front Control Panel Header Pins (JF1)5-4 I/O PortsThe I/O ports on the motherboard are located a

Page 72 - 5-12 Installing Software

Chapter 5: Advanced Motherboard Setup5-95-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUTIONExercise extrem

Page 73 - SuperDoctor III

5-10SUPERSERVER 5018D-MF User's ManualPopulating these DIMM modules with a pair of memory modules of the same type and same size will result in i

Page 74 - 5-13 Onboard Battery

Chapter 5: Advanced Motherboard Setup5-11Possible System Memory Allocation & AvailabilitySystem Device SizePhysical Memory Remaining (-Available)(

Page 75 - Advanced Chassis Setup

5-12SUPERSERVER 5018D-MF User's Manual5-6 Adding PCI CardsPCI Expansion SlotsOne riser card is used to support a PCI expansion (add-on) card in

Page 76 - 6-2 Control Panel

Chapter 5: Advanced Motherboard Setup5-13Figure 5-4. SUPER X10SLL-F Layout5-7 Motherboard DetailsFAN2JP9SW1T-SGPIO1JSTBY1JIPMB1JPW2JSD1LED3LED2JD1LED

Page 77 - 6-3 System Fans

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Page 78 - Accessing the Drive Bays

5-14SUPERSERVER 5018D-MF User's ManualUSB 4/5, 6/7 (2.0) Backpanel USB 2.0 Ports 4/5, 6/7USB 8/9 Front Panel Accessible USB 2.0 Headers 8/9VGA Ba

Page 79 - DVD-ROM Drive Installation

Chapter 5: Advanced Motherboard Setup5-155-8 Connector Defi nitions Processor PowerPin Defi nitions (JPW2)Pins Defi nition 1/2 Ground

Page 80

5-16SUPERSERVER 5018D-MF User's ManualNIC1/NIC2 (LAN1/LAN2)The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pin

Page 81 - 6-5 Power Supply

Chapter 5: Advanced Motherboard Setup5-17Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins

Page 82

5-18SUPERSERVER 5018D-MF User's ManualFan HeaderPin Defi nitions Pin# Defi nition 1 Ground (Black)2 +12V (Red)3 Tachometer4 PWM_ControlFan

Page 83 - Chapter 7

Chapter 5: Advanced Motherboard Setup5-19Power Supply I2C ConnectorThe Power Supply (I2C) connector is located at JPI2C on the motherboard. This conne

Page 84 - 7-2 Main Setup

5-20SUPERSERVER 5018D-MF User's ManualDOM PWR ConnectorThe Disk-On-Module (DOM) power con-nector, located at JSD1, provides 5V (Gen1/Gen) power t

Page 85

Chapter 5: Advanced Motherboard Setup5-215-9 Jumper SettingsExplanation of JumpersTo modify the operation of the mother-board, jumpers can be used to

Page 86 - Boot Feature

5-22SUPERSERVER 5018D-MF User's ManualLAN Port Enable/DisableUse JPL1/JPL2 to enable or disable LAN Ports 1 and 2 on the motherboard. See the tab

Page 87 - Power Confi guration

Chapter 5: Advanced Motherboard Setup5-23Management Engine (ME) Recovery Use Jumper JPME1 to select ME Firmware Recovery mode, which will limit resour

Page 88 - CPU Confi guration

viiTable of ContentsNIC2 ... 3-2NIC1 ...

Page 89

5-24SUPERSERVER 5018D-MF User's Manual5-10 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On eac

Page 90

Chapter 5: Advanced Motherboard Setup5-255-11 SATA Drive ConnectionsSATA Port Pin Defi nitionsPin # Defi nition 1 Ground2 TXP3 TXN4 Gro

Page 91

5-26SUPERSERVER 5018D-MF User's Manual5-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp

Page 92

Chapter 5: Advanced Motherboard Setup5-27SuperDoctor IIIThe SuperDoctor® III program is a web-based management tool that supports remote management ca

Page 93 - • VT-d Capability

5-28SUPERSERVER 5018D-MF User's Manual5-13 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in any way; a damaged

Page 94 - Memory Confi guration

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Page 95 - PCH-IO Confi guration

6-2SUPERSERVER 5018D-MF User's Manual6-2 Control PanelThe control panel (located on the front of the chassis) must be connected to the JF1 connec

Page 96

Chapter 6: Advanced Chassis Setup6-36-3 System FansThe 5018D-MF employs two sets of 4-cm counter-rotating fans to provide cooling. Each fan unit is ma

Page 97 - • Software Preserve Support

6-4SUPERSERVER 5018D-MF User's Manual6-4 Drive Bay Installation/RemovalAccessing the Drive BaysDVD-ROM/Serial ATA Drives: For installing or remo

Page 98

Chapter 6: Advanced Chassis Setup6-5Serial ATA Drive Installation The SATA drive is not hot-swappable, meaning system power must be turned off before

Page 99

viiiSUPERSERVER 5018D-MF User's Manual5-10 Onboard Indicators ...

Page 100 - ACPI Settings

6-6SUPERSERVER 5018D-MF User's ManualFigure 6-3. Removing the DVD-ROM Drive3. Carefully lift the server out of the rack.4. Open the cover by f

Page 101 - Super IO Confi guration

Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe 5018D-MF has a single 350 watt power supply. This power supply has the capability of operating

Page 102 - Console Redirection Settings

6-8SUPERSERVER 5018D-MF User's Manual5. Reconnect the power cord, replace the chassis top cover and push the unit back into the rack.6. Finish

Page 103

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X10SLM-F/X10SLL-F/X10SLL-SF/X10SLL-S . Th

Page 104

7-2SUPERSERVER 5018D-MF User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory tes

Page 105 - 7-4 Event Logs

Chapter 7: BIOS7-3The following Main menu items will be displayed:System Time/System Date Use this option to change the system time and date. Highligh

Page 106 - View SMBIOS Event Log

7-4SUPERSERVER 5018D-MF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and press <Enter> to access

Page 107 - • IPMI Status

Chapter 7: BIOS7-5Bootup Num-LockThis feature selects the Power-on state for the Numlock key. The options are Off and On.Wait For 'F1' If Er

Page 108 - BMC Network Confi guration

7-6SUPERSERVER 5018D-MF User's ManualCPU Confi gurationThe following CPU information will be displayed:• Type of CPU• CPU Signature• Microcode Pa

Page 109 - 7-5 Boot Settings

Chapter 7: BIOS7-7Hyper-threadingSelect Enabled to support Intel Hyper-threading Technology to enhance CPU per-formance. The options are Enabled and D

Page 110

Chapter 1 Introduction1-1 OverviewThe SuperServer 5018D-MF is a high-end server comprised of two main subsys-tems: the SC512F-350B 1U server chassis a

Page 111 - 7-6 Security Settings

7-8SUPERSERVER 5018D-MF User's ManualCPU AESSelect Enable to enable Intel CPU Advanced Encryption Standard (AES) Instruc-tions for CPU to enhance

Page 112 - 7-7 Save & Exit

Chapter 7: BIOS7-91-Core Ratio Limit (Available when "Turbo Mode" is set to Enabled)This increases (multiplies) 1 clock speed in the CPU cor

Page 113

7-10SUPERSERVER 5018D-MF User's ManualCPU C3 Report (Available when "CPU C-States" is set to Enabled)Select Enabled to allow the BIOS t

Page 114

Chapter 7: BIOS7-11LakeTiny FeatureSelect Enabled for LakeTing feature support. The options are Disabled and En-abled.ACPI T StateSelect Enabled for A

Page 115 - BIOS Error Beep Codes

7-12SUPERSERVER 5018D-MF User's ManualThis item allows the generation confi guration of PEG0 on the PCI-E slot. The options are Auto, Gen1, Gen2

Page 116

Chapter 7: BIOS7-13• CAS Latency (tCL)• Minimum Delay Time• CAS to RAS (tRCDmin)• Row Precharge (tRPmin)• Active to Precharege (tRASmin)Memory Frequen

Page 117 - System Specifi cations

7-14SUPERSERVER 5018D-MF User's ManualEHCI2Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 2 for USB 2.0 support. O

Page 118

Chapter 7: BIOS7-15SATA Confi gurationof the SATA Devices and displays the following items:SATA ControllersThis item Enables or Disables the built-in

Page 119

7-16SUPERSERVER 5018D-MF User's ManualSerial ATA Port 0~ Port 5This item displays the information detected on the installed SATA drives on the pa

Page 120

Chapter 7: BIOS7-17VGA Palette SnoopSelect Enabled to support VGA palette register snooping which will allow the PCI cards that do not contain their o